Calibration

1. Check to be sure installation of all parts is complete, all fasteners are
secure and the Encoder is plugged into the Readout.
2. Cut a small part (approximately 8 inches) using the stop. DO NOT MOVE
THE STOP UNTIL THIS PROCEDURE IS COMPLETED.
3. Measure the length of the part with the most precise measuring tool you
have available (preferably digital calipers).
4. Press the
Datum
(PLUS) key to change the reading until the length you just measured is
shown (The longer the + key is held down, the faster the readout will scroll).
This adjustment should be made in a decimal (inches or mm) mode for the
best accuracy.
5. When the correct reading is reached,
prevents accidentally re-zeroing during normal use.
See Section 3: Readout Lock Mode

Changing the Battery

A low battery indicator will appear in the lower left corner of the LCD.
When battery voltage drops below approximately 2.6V the readout will
turn itself off until the batteries are replaced.
To replace the battery remove the screws in the upper right and lower left
corners. Pull the cover off. Remove the old battery and install a new CR123
(or equivalent) Lithium battery. Replace the cover and tighten the screws.
Manual Part # 800-1070-001 Rev 10-2016
key to 'zero' the readout, then press and hold the +
lock
the readout if desired. This