Circa Enterprises Guardian P5521 Manual de instalação e operação - Página 8
Procurar online ou descarregar pdf Manual de instalação e operação para Invólucro Circa Enterprises Guardian P5521. Circa Enterprises Guardian P5521 16 páginas. Page/talk indoor housing
Guardian Telecom
Assignment
System Power
Ambient Noise
Microphone
Speaker
Page Line
Channel
Group Muting of
Loudspeakers
Spare Conductor
(Special Order)
Note:
Channels 2 to 5 connections remain empty for single Talk Line hookup.
If this station is in a Group Muting series, but is not to be muted when paging calls are made from
other stations in the group, connect the wires assigned to this function to the Park terminals.
Figure 7 - Wiring
Designation
Description
J4A/J5A
HOT
J4A/J5A
COM
J4A/J5A
GND
J6A
MIC +
J6A
MIC -
J7A
SPK +
J7A
SPK -
J2A/J3A
PA
Page Line
J2A/J3A
PB
J2A/J3A
1A
Channel 1
J2A/J3A
1B
J2A/J3A
2A
Channel 2
J2A/J3A
2B
J2A/J3A
3A
Channel 3
J2A/J3A
3B
J2A/J3A
4A
Channel 4
J2A/J3A
4B
J2A/J3A
5A
Channel 5
J2A/J3A
5B
J2A/J3A
Mute
J2A/J3A
Park
n/a
Extra
Figure 8 - Electrical Connections
Page 8
Installation and Operation
Page/Talk Indoor Housing
Jacket
Stripe
Color
Black
White
Green
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Blue
Red
"
Red
Blue
Red
"
L. Brown
Red
Violet
"
L. Brown
Violet
Blue
"
L. Brown
Blue
Brown
"
L. Brown
Brown
Yellow
"
L. Brown
Yellow
Orange
Red
Wire
Color
Gauge
14 AWG
14 AWG
14 AWG
n/a
n/a
n/a
n/a
18 AWG
"
18 AWG
"
18 AWG
"
18 AWG
"
18 AWG
"
18 AWG
"
18 AWG
"
12 AWG