CIRCLE FITNESS R8 Manual de serviço - Página 8
Procurar online ou descarregar pdf Manual de serviço para Bicicleta de exercício CIRCLE FITNESS R8. CIRCLE FITNESS R8 16 páginas.
Também para CIRCLE FITNESS R8: Manual de serviço (9 páginas), Manual de serviço (20 páginas)
2. Error Signal Check and Solutions
Item
Error Message
1.
COMMUNICATION FAIL
2.
DC BUS ERROR
3.
DCV VOLT OVERLOAD
4.
DCV VOLT OVERVOLT
Document:
Service Manual
Description:
Elliptical/Upright Bike/ Recumbent Bike
Model:
E7/B8/R8
Descriptions
CAUSE: Communication timeout. This error message
pops up if console and generator lose communication for
over 90 seconds.
SOLUTION:
- Check that the console and generator are connected
properly.
- If the connection is correct, please replace the console or
generator.
CAUSE: The generator cannot transform AC power to DC
power.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The voltage of DC generator is too high (over
300V for 3 seconds). User may be peddling too fast
(normal peddling speed should be under 180 RPM).
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The voltage of DC generator is too high (over
300V for 3 seconds). User may be peddling too fast
(normal peddling speed should be under 180 RPM).
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
8
Display Type:
LED
Page:
8
of 16
Release Date:
2017/08/31