7
Technical data
Manufacturer
Address
Power supply
Voltage
Max current (resistive load)
Min current (resistive load)
Total current consumption
General
Degree of protection
Ambient temperature
Connector
Size
Actuating force
Actuator travel
Mechanical life
Colour
Weight
Material
Chemical resistance at 20°C
Alcohols
Paraffin oil
Milk
Silicon oil
Acetone
Please contact ABB/Jokab Safety for more information regarding other substances.
2TLC172180M0201, rev. A
2011-10-20
ABB AB / JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
24 VDC. Tolerance 5 – 30 VDC
2 A at 30 VDC (max)
20 mA at 24 VDC (recommended)
10 mA at 6 VDC
< 50 mA
IP67 - not intended for use under water.
-25...+50°C
2
4x connection cables, 0.75 mm
See drawing
Approx. 2 N
1.3 ± 0.6 mm
6
> 1*10
operations at max 1 Hz
Yellow and black
JSTD1-B, -E: 95 g
JSTD1-A: 225 g (with 2 m cable)
JSTD1-C: 680 g (with 10 m cable)
Polypropene
Good
Good
Good
Good
Good
13
. Length depending on model.
www.jokabsafety.com