CREE LIGHTING FLX22-10V1 Manual de instruções
Procurar online ou descarregar pdf Manual de instruções para Equipamento de iluminação CREE LIGHTING FLX22-10V1. CREE LIGHTING FLX22-10V1 6 páginas.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l'alimentation avant l'installation.
2.
This luminaire must be installed in accordance with the NEC or your local
electrical code. If you are not familiar with these codes and requirements,
consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n'êtes pas familier avec ces codes et ces
exigences, veuillez contacter un électricien qualifié.
3.
Suitable for Damp Locations.
Convient aux emplacements humides.
4.
Access above ceiling required. Do not install insulation within 3 inches (76
mm) of any part of the luminaire. Suitable for suspended ceilings.
Acces requis au-dessus du plafond. Ne pas mettre l'isolant a moins de 76
mm (3 po) de toute partie du luminaire. Convient aux plafonds suspendus.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
• The FLX Series of specification
troffers is for non-insulated ceiling
applications using T-Bar ceiling
grid, drywall grid adaptors, or
suspended mount.
• Designed for use in 120-277V
50/60 Hz or 347V 50/60 Hz
protected circuit (fuse box, circuit
breaker). Supply wire sized as per
NEC or governing code(s), 90C
rated. Note: 347V 50/60Hz are
designed for 347V only and are
separate skus from 120-277V
TO INSTALL:
1
Luminaire Hooks
1 of 3
• Make sure to cap off all unused
leads.
• Lens and removable end cap may
shift during installation. To seat
lens press end caps and squeeze
lens to engage with back panel.
• NOTE: Actual Lens provided may be
visually different than illustrated.
• NOTE: Power whip is not for -CP
applications.
T-bar
Includes: FLX14-10V1 / 10V10, FLX22-10V1 / 10V10, FLX14-10V1 / 10V10
FLX14-10V1
FLX14-10V10
FLX22-10V1
FLX22-10V10
FLX24-10V1
FLX24-10V10
• See the product label for exact ratings since the
following is generic in the manual for all models in
the series.
1st:
90° Bend
2nd: Bend
Against T-bar
T-bar
FLX Series
Specification Troffers
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION
T- BAR CEILING
MOUNTING
STEP 1:
Bring the FLX troffer up into
the T-Bar grid.
STEP 2:
Locate the luminaire hooks and
bend them out 90 degrees for
installation. See Figure 1.
NOTE: The luminaire hooks
ship bent in and need to be
bent out for installation.
STEP 3:
Then bend the luminaire hooks
against the T-Bar to secure the
luminaire. See Figure 1.
LPN00437X0004A0_A