Digiflex RF112 Manual de referência de instalação

Procurar online ou descarregar pdf Manual de referência de instalação para Acessórios Digiflex RF112. Digiflex RF112 2 páginas. Smart rf wireless contact /shock sensor / analyse

Digiflex RF112 Manual de referência de instalação
D
X
IGIFLE
®
RF112 - SMART RF
Wireless Contact /Shock
Sensor / Analyser
Installation Reference Guide
Rev1.6
The RF112 Ships With The Following Items
RF112 Printed Wiring Assembly
RF112 Housing Including Cover And Mounting Plate
Double Sided Adhesive Tape To Suit Above Housing
Magnet Housing Including Cover And Mounting Plate
Double Sided Adhesive Tape To Suit Above Housing
Neodymium Magnet
CR123A Lithium Battery
5 x Mounting Screws and 1 x Case Lock Screw
RF112IRG Installer Reference Guide
Ensure that the transmitter is protected from
weather elements such as extreme temperatures,
humidity, rain or snow.
D
X
IGIFLE
P
L
TY
TD
18 Brumby Street
Seven Hills NSW 2147, AUSTRALIA
Phone:
(+612) 97417000
Email:
Web:
www.digiflex.com.au
Our Vision Is Your Peace Of Mind
29.6 mm
30.4 mm
54 mm
17.4mm
13.5 mm
0-93% Relative Humidity
Non-condensing
433.42 Mhz
Functional range: -10°C to +49°C
EN5013-5 Class II Only: -10°C to +40°C
Panasonic CR123A Lithium
Duracell DL123A
3.0 VDC
?
For Further Information See Your
Control Panel Installation Manual
4
Mounting
5
Battery Installation
Tamper
Mounting
Screw
Case Front
Tamper
!
Tamper
Screw
Mounting
Screw
Panasonic : CR123A
Cable Entry
Duracell : DL123A
Knockout
1
Opening The Housing
Push the screwdriver blade
3mm into the slot shown.
Do Not twist the blade!
Lift the screwdriver away from the
base to release the cover. Do not
twist or rotate the screwdriver.
B
Case Locking Screw
10mm
C
Max
4G x10
Philips #1
Alarm
6
N/C
Wiring
ZONE
(EOL)
1= INPUT 1
2= COMMON
Single EOL
3= 3V OUT
4= GND
5= INPUT 2
6= COMMON
Alarm
Tamper N/C
N/C
TAMPER
ZONE
(EOL)
EOL Alarm+Tamper
Contact Wiring Distance = 8m MAX
All other external peripherals = 1m MAX
3V D.C. Output
Powering external devices from this
output will reduce battery life.
Shock Sensor/Rope Contact Input
For further information refer to
Control Panel Install Manual
2
Removing The PWA
A
3
RF ID
RF ID is located on the
side of the battery holder.
Input 1
7
Using Adhesive Mounting
The RF112 is supplied with a double sided tape
1
mounting option. Use this mounting method to speed
2
installation where appropriate.
Follow the guidelines below for best results.
1) Do not use on rough or uneven surfaces.
2) Clean both surfaces using isopropyl alcohol wipes
End Of Line Resistor (EOL)
For further information refer
before installing tape.
to Control Panel EOL Selection
3) Test zone function to ensure correct placement before
removing backing tape.
Input 1
4) Apply firm pressure to the device for 30 seconds
after placement to ensure the adhesive activates. (The
1
adhesive is pressure activated)
(EOL)
2
8
LED Indicator
6 Slow Flashes
3
4 Fast Flashes
4
Continuous Flash
Single Pulse
Input 2
When panel is in service mode and device Tamper is
triggered, the LED will activate for up to 15 minutes
5
to assist with device placement and configuration.
During normal operation the LED is off to extend
6
battery life.
Do Not Lift
By Antenna
Move
Plastic Tab
Lift PWA Out
Device Powered Up
Device Has been Configured
Device TX or RX
Device Input Triggered
RF112IRG Rev1.6 P/N DF2382