Cres Cor H137WSUA5DMFBC Manual de Instruções de Operação e Manutenção - Página 2

Procurar online ou descarregar pdf Manual de Instruções de Operação e Manutenção para Aquecedor de alimentos Cres Cor H137WSUA5DMFBC. Cres Cor H137WSUA5DMFBC 8 páginas. Humidity holding hot cabinet

Insulated
FL-2355-BC
Hot Cabinets
Rev. 2 (12/20)
Page 2 of 8
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE'S PROGRAMMING REVISION J-08
ACTUAL CABINET
TEMPERATURE
HOW TO HOLD:
No water is needed in pan.
1. Push the switch on; the light will come on.
NOTE: The letters "LOTPR" will show on the control
panel until it reaches 80°F (26°C).
2. Push and hold knob for 5 seconds, then turn to
a temperature between 140°F (60°C) and 220°F
(104°C). Push the knob to set the temperature.
3. Preheat the cabinet for 30 minutes.
NOTE: Press the "Display" button to see the actual
X:\ENGINEER\FLSHEETS\FL2355 CONTROL PANEL
temperature inside the cabinet.
HOW TO HOLD WITH HUMIDITY:
Fill water pan with 4 gallons (15 liters) of HOT
water.
1. Push the switch on; the light will come on.
NOTE: The letters "LOTPR" will show on the control
panel until it reaches 80°F (26°C).
2. Push and hold knob for 5 seconds, then turn to a
temperature between 80°F (26°C) and 220°F (104°C).
Push the knob to set the temperature.
3. Push and hold knob for 5 seconds, then turn knob to
desired humidity value setting. Push the knob to set
the value number.
4. Preheat the cabinet for 1/2 hour (30 minutes).
NOTE: This cabinet operates with air temperature
priority. Humidity will only start after cabinet
is fully preheated. If cold or room temp water is
used, humidity build-up time will be longer.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
"ON-OFF" SWITCH
"HOT HOLDING"
DIGITAL CONTROL
ON-OFF
DIGITAL CONTROL NOTES
*Press the "display" button to see the actual temperature
inside the cabinet (press again to shut off).
*Press the "display actual" button to see the approximate
relative humidity value (press again to shut off).
*Small letters in upper right corners of the displays are:
Hot Holding control: "S" = setpoint temperature
AquaTemp control:
NOTE: When the low water light is on, the "A"
NOTE: These settings are based on laboratory
"AQUATEMP"
DIGITAL CONTROL
LOW WATER LIGHT
HUMIDITY READING
"A" = actual temperature
"S" = setpoint reading
(in increments of 5)
"A" = approximate relative
humidity reading
numbers will not be close to an accurate
reading, and the water heater will not heat.
conditions and may differ from conditions at the
point of use. Experiment with the settings
to determine what is best for your application.