Cres Cor 500CHSKD120 Manual de instalação, operação e manutenção - Página 12
Procurar online ou descarregar pdf Manual de instalação, operação e manutenção para Fumadores Cres Cor 500CHSKD120. Cres Cor 500CHSKD120 15 páginas. Radiant smoker ovens
FL-2375
Smoker Ovens
Rev. 1 (6/14)
Page 12 of 15
WARNING
1. Cord is unplugged from wall outlet.
2. Circuit breaker/fuse to wall outlet is blown.
IF THE OVEN TURNS ON:
PROBLEM
Oven does not heat, or doesn't heat
properly
Heater will not shut off
Vent fans do not shut off
Vent fans do not operate (See Note)
Control will not switch from "COOK" to
"HOLD" (timed mode)
Control will not switch from "COOK" to
"HOLD" (probe mode)
Control will not switch to "COOK" (probe
mode)
ERROR CODES:
CODE DISPLAYED
no p
Err0
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement
of electrical components must be done by a qualified electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers.
Instructions for replacing parts are included in replacement parts list.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE
IF UNIT GETS TOO HOT OR WON'T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
If hot unit is NOT working, first check the following causes:
POSSIBLE CAUSE
1. Sensor
2. Heater relay
3. Loose connection
4. Oven control
5. High Limit
1. Control defective
2. Heater relay
1. Vent fan switch defective
2. Control compartment is still hot.
1. Vent fan switch defective
2. Vent fan defective
1. Oven is in "PROBE" mode.
2. Oven control defective
1. Oven is in the "TIMED" mode
2. Probe not plugged in
3. Probe defective
4. Oven control defective
1. Oven in "TIMED" mode
2. Probe temperature setting lower
than probe temperature
3. Probe not plugged in
4. Oven control defective
CAUSE
No meat probe
Temp probe bad
5925 Heisley Road • Mentor, OH 44060-1833
3. Switch(es) are turned off.
4. Thermostat(s) are turned off, or are set too low.
SOLUTION
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
1. Replace
2. Replace
1. Replace
2. Wait until it cools
Check "Heater will not shut off"
1. Replace
2. Replace
1. Cancel recipe and switch to "TIMED" mode
2. Replace
1. Cancel recipe and switch to "PROBE" mode
2. Plug in probe
3. Replace
4. Replace
1. Switch to "PROBE" mode
2. Set probe temperature to desired temperature
3. Plug in probe
4. Replace
SOLUTION
Plug in probe
Replace