2.4.
INSTALLATION INSTRUCTIONS
The C7 amplifier is designed for installation in a rack (Figures 2-1 and 2-2) that permits
access to the rear of the rack for connection of DC power, RF, and monitor cable. The
amplifier must have a minimum of 3 inches of open space in front of and behind the rear fan
to allow adequate ventilation.
To install the amplifier proceed as follows:
1. Install FPR-5 subrack into a 19 inch equipment rack using the front and rear
mounting points
2. Install amplifier in subrack and secure in place with two thumbscrews on front
panel.
3. Connect a 50 ohm antenna cable and load to the RF OUT connector on rear of
amplifier.
4. Connect the transceiver/exciter output to RF IN connector on rear of amplifier.
5. If monitoring of PA is desired, connect alarm cable to "ALARM" pin on rear of
amplifier module. See section 2.5 for more details.
6. Measure primary DC input voltage. DC input voltage should be +13.8 +/- 0.1VDC.
Turn off DC voltage.
WARNING: Turn off external primary DC power before connecting DC power cables.
7. Connect positive primary power wire (+13.8VDC) to terminal marked +13.8VDC
and negative primary power wire to GND terminal on rear of amplifier.
8. Check your work before applying DC voltage to the system. Make certain all
connections are tight and the DC wires are going to the correct terminals.
9. Refer to Section 3 for initial start-up procedures.
NOTE:
1. Make sure power supply DC is well filtered and well behaved with minimal
voltage overshoot.
2. Keep DC wires as short as possible to minimize inductance induced voltage
transients.
3. Size DC Wires properly to handle the load current to minimize voltage drop.
Copyright Crescend Technologies
Figure 2-1. FPR-5 Rack, Front Right View
9