Digiplex DGP-641ACC Manual de programação
Procurar online ou descarregar pdf Manual de programação para Teclado Digiplex DGP-641ACC. Digiplex DGP-641ACC 2 páginas. Access control lcd keypad
Também para Digiplex DGP-641ACC: Manual de programação (2 páginas)
Access Control LCD Keypad V1.1
DGP-641ACC
Programming Guide
P
M
ROGRAMMING
ETHOD
STEP 1: Press and hold the [0] key
STEP 2: Enter the [
INSTALLER CODE
STEP 3: Enter section [953]
STEP 4: Enter the keypad's 8-digit [
STEP 5: Enter the 3-digit [
STEP 6: Enter the required data
To view the keypad's serial number, press and hold the [0] key,
enter the [
INSTALLER CODE
you use this sheet to keep track of which sections were
programmed and how. This module can also be programmed using
Module Broadcast (see Digiplex Installation & Reference Manual).
B
V
US
OLTMETER
To verify if the bus is supplying sufficient power, press and hold the
[0] key, enter the [
INSTALLER CODE
A reading of 9.2V indicates that the voltage is too low. The
voltage may drop during the control panel battery test.
P
S
ROGRAMMING
ECTIONS
Bold = default setting.
SECTION [001]: Partitioning
Option
[1]
Partition 1
[2]
Partition 2
[3]
Partition 3
[4]
Partition 4
[5]
Assign Door to Partition 1
[6]
Assign Door to Partition 2
[7]
Assign Door to Partition 3
[8]
Assign Door to Partition 4
SECTION [002]: General Options
Option
[1]
Display Code Entry
[2]
Display Exit Delay
[3]
Display Entry Delay
[4]
Confidential Mode
(not for UL installations)
[5]
To Exit Confidential Mode
[6]
Reader's red LED to follow
Partition's status
[7]
R eader's beeping to follow
P artition's status w hen [6] O N
[8]
Not used
] (by default 000000)
]
SERIAL NUMBER
] you want to program
SECTION
] and enter [000]. We recommend that
] and press [
].
ACC
OFF
ON
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
OFF
ON
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Enter Code
!" Press Button
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" N/A
!" N/A
SECTION [003]: General Options
Option
[1]
Muting
[2]
Exit Delay Beep
[3]
Door Left Open Pre-Alarm
[4]
Chimed Zone Closure
[5]
Door Left Open Alarm
[6]
D oor Left O pen Alarm follow s
[7]
Door Forced Alarm
[8]
Door Forced Alarm follows
SECTION [004]: Beep on Trouble
Option
S ystem & C lock Trouble Beep !" Disabled
[1]
Communicator Trouble Beep !" Disabled
[2]
Module & Bus Trouble Beep !" Disabled
[3]
[4]
All Zone Trouble Beeps
[5] to [8]Not used
SECTION [005]:
General Options
Option
[1]
Card Activates Door
Unlocked Schedule
[2]
Door Left Open Alarm
[3]
Door Forced Open Alarm
[4]
Not used
[5]
Keypad Tamper
[6]
Door will Relock
[7]
Reader's Green LED for
Access Granted
[8]
Unlock on REX
SECTION [006]
Door Unlocked Period (001-255 seconds)
___/___/___ (default = 005)
SECTION [007]
Door Unlocked Period Extension (001-255 seconds added to [006])
___/___/___ (default = 015)
SECTION [008]
Door Left Open Interval (001-255 seconds)
___/___/___ (default = 060)
SECTION [009]
Door Left Open Pre-Alarm Timer (001-255 seconds)
Time to start Pre-Alarm before alarm is triggered.
___/___/___ (default = 015)
SECTION [010]
Beep Timer for Door Left Open Alarm (001-255 seconds)
Amount of time Door Left Open alarm will beep.
___/___/___ (default = 005)
SECTION [011]
Beep Timer for Door Forced Open Alarm (001-255 seconds)
Amount of time Door Forced Open alarm will beep.
___/___/___ (default = 005)
SECTION [012]: Door Unlocked Schedule
Start time
End time
A:
___ ___:___ ___ ___ ___:___ ___ 1 2 3 4 5 6 7 8
OFF
ON
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Silent
!" Audible
!" Alarm Restore !" Beep Timer
!" Silent
!" Audible
!" Alarm Restore !" Beep Timer
OFF
ON
!" Enabled
!" Enabled
!" Enabled
!" Disabled
!" Enabled
!" N/A
!" N/A
OFF
ON
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" Disabled
!" Enabled
!" N/A
!" N/A
!" Disabled
!" Enabled
!" Immediately
!" When closed
!" Disabled
!" Enabled
!" Disabled
!" Enabled
Days
(turn
or
)
ON
OFF
S M T W T F S H