Cisco AP776A - Nexus Converged Network Switch 5020 Nota de lançamento - Página 23

Procurar online ou descarregar pdf Nota de lançamento para Interruptor Cisco AP776A - Nexus Converged Network Switch 5020. Cisco AP776A - Nexus Converged Network Switch 5020 26 páginas. Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Também para Cisco AP776A - Nexus Converged Network Switch 5020: Nota de lançamento (48 páginas), Nota de lançamento (44 páginas), Nota de lançamento (26 páginas), Nota de lançamento (22 páginas), Manual de referência rápida (14 páginas), Nota de lançamento (3 páginas)

Cisco AP776A - Nexus Converged Network Switch 5020 Nota de lançamento
S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
Resolved Caveats—Cisco NX-OS Release 4.0(0)N1(2)
This section lists the resolved caveats for this release.
OL-16601-01
CSCsu32247
Symptom: The Nexus 5000 Series switch executes the power-on self-test (POST) at bootup to
validate hardware integrity of the ASICs. When a Fibre Channel port is connected to a host bus
adapter (HBA), the HBA driver can trigger a signal loss that causes a false failure to be reported by
POST for one of the ASICs. As a result, all the ports serviced by the ASIC on the GEM are marked
for hardware failure.
Workaround: Do not connect HBAs to the FC expansion modules.
CSCsu40126
Symptom: When the Cisco Nexus 5000 Series switch is configured to operate in the N-port
virtualization (NPV) mode, the LOGOs received over the server port are not processed properly.
This results in stale Fibre Channel IDs at the switch.
Workaround: Perform shut and no shut command operations on all the server ports to clear the
stale state on the NPV switch.
CSCsm66194 and CSCsr66209
Symptom: Logins may not be uniformly balanced across all available border ports when the Cisco
Nexus 5000 Series switch operates in the NPV mode under conditions such as the following:
The switch is reloaded.
NPIV is disabled and re-enabled on the NPV core-switch.
The NPV core-switch is reloaded.
A new NP link is added.
Workaround: Perform shut and no shut command operations on all the server ports to rebalance
the logins.
CSCsu25775
Symptom: When the Cisco Nexus 5020 Series switch is connected to a 110 V power supply, the
following problems occur:
The syslog displays warnings at bootup. Although the hardware supports the 110 V input, the
operating system incorrectly logs the warning message.
The show environment power command incorrectly displays the available power as a negative
value.
Workaround: The problem is not significant and the system operates normally with 110 V power
supply input. There is no workaround to avoid the syslog message.
CSCsq61505
Symptom: Problems are encountered while upgrading to Cisco NX-OS Release 4.0(0)N1(2) from
Cisco NX-OS Releases 4.0(0)N1(1) or 4.0(0)N1(1a).
Workaround: None.
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, Release 4.1(3)N1(1)
Caveats
23