Accustic Arts MONO III MK2 Manual - Página 9

Procurar online ou descarregar pdf Manual para Amplificador Accustic Arts MONO III MK2. Accustic Arts MONO III MK2 13 páginas.

IMPORTANT!
Avoid short circuits!
Never connect the output terminals of your power amplifier to each other. Neither connect
red (+) with white or black (-) of the channel nor the channels to each other.
4. 5 Connection to mains power
Only connect the power amplifier to the mains power when all the other cable connections have already been
carried out. Plug in the mains cable firstly in the inlet connector socket 1 of the power amplifier and only then the
earthing pin-plugs in the mains socket.
By actuating the mains power switch 13, you can switch the unit on or off. For further details, please read chapter
5.
2.
4. 6 Replacing damaged mains fuses
Replace fuses only with original types having the same ampere value, the same voltage endurance and the same
time-lag. Never use fuses with other ampere classes or time-lag classes.
IMPORTANT!
Pull out the mains plug!
Always disconnect the unit from the mains power before replacing a fuse.
To change the fuses FUSE 1 and FUSE 2 please use a screwdriver suitable for the slot in the fuse holder. Press the
screwdriver lightly into the slot and only then turn anticlockwise. Now you can take out the fuse holder and replace
the fuse.
For countries with 220 - 240 V / 50-60 Hz
please use the following fuse types:
Fuse F1 / F2: 10 Ampere, time lag
For countries with 100 - 120 V / 50-60 Hz
please use the following fuse types:
Fuse F1 / F2: 16 Ampere, time lag
10