S E R V I C E C A L L C H E C K
Please check the following before calling for service:
1. Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for two minutes on Microwave, HIGH 100% power.
A. Does the oven light come on?
B. Does the cooling fan work?
(Put your hand over the air vent opening at the top.)
C. Is the water in the oven hot?
2. Remove water from the oven and operate the oven for 5 minutes on Manual Convection, Bake or Roast 450°F.
A. Does the Convection icon
B. After the oven steps, is inside of the oven hot?
3. Fill the reservoir with water and replace.
Operate the oven for 3 minutes on Manual Steam.
A. After the oven steps, is the inside of the oven filled with steam?
If "NO" is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit
breaker. If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER. A
microwave oven should never be serviced by a "do-it-yourself" repair person.
S P E C I F I C A T I O N S
AC Line Voltage:
AC Power Required:
Output Power:
Microwave
Convection Heater
Frequency:
Outside Dimensions (WxHxD):
Cavity Dimensions (WxHxD)
Oven Capacity
:
**
Weight:
The International Electrotechnical Commission's standardized method for measuring output wattage. This test
*
method is widely recognized.
Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food
**
is less.
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, NJ 07495-1163
SEC AX1200 O/M,P36-
appear in the display?
CONV
Single phase 120V, 60Hz, AC only
1.04 kW 9.0A (Microwave)
1.50 kW 12.5A (Convection)
700W
(IEC Test Procedure)
*
1450W
2450 MHz
22 3/
"(H) x 18 3/8"(D)
"(W) x 17
1
/
8
4
568 mm x 438 mm x 468 mm
:
14
1
/
"(W) x 10
1
/
"(H) x 13
**
8
8
359 mm x 256 mm x 339 mm
1.1 cft
Approx. 60 lbs.
®
41
YES _______
YES _______
YES _______
YES _______
YES _______
YES _______
3
/
"(D)
8
41
08.9.25, 8:48 AM
NO _______
NO _______
NO _______
NO _______
NO _______
NO _______
TINSEB183WRRZ-D81