ELECTRICAL GROUNDING INSTRUCTIONS
This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. It must be
plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local
codes and ordinances. In the event of an electrical short circuit, grounding reduces risk of electric shock by providing an escape
wire for the electric current.
WARNING
- Improper use of the grounding plug can result in a risk of
electric shock.
The oven is equipped with a 3-prong grounding plug. DO NOT UNDER
ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN
FROM THE PLUG.
The Power Supply Cord and plug must be connected to a separate
120 Volt AC, 60 Hz, 15 Amp, or more branch circuit, single grounded
receptacle. The receptacle should be located inside the cabinet directly
above the Microwave Oven/Hood mounting location.
NOTE:
1. If you have any questions about the grounding or electrical instruc-
tions, consult a qualified electrician or serviceperson.
2. Neither Sharp nor the dealer can accept any liability for damage to
the oven or personal injury resulting from failure to observe the
correct electrical connection procedures.
4
HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must be metal; absolutely do not use plastic
duct. Check that all connections are made securely. Please read the following carefully:
Exhaust connection: The hood exhaust has been designed to connect to a standard 3-1/4" x 10" rectangular duct. If round duct
is required, a rectangular-to-round adapter must be used.
Rear exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the space between the
studs, or wall should be prepared at the time it is constructed by leaving enough space between wall studs to accommodate
exhaust.
Maximum duct length: For satisfactory air movement, the total
duct length of 3-1/4" X 10" rectangular or 6" diameter round duct
should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present additional
resistance to air flow and are equivalent to a section of straight
duct which is longer than their actual physical size. When
calculating the total length, add the equivalent lengths of all
transitions and adapters plus the length of all straight duct
sections. Figure 3 shows the approximate feet of equivalent
length of some typical ductwork parts. Use the values in
parentheses for calculating air flow resistance equivalent, which
should total less than 140 feet.
5
TOOLS RECOMMENDED FOR INSTALLATION
• Phillips Screwdriver
• Electric Drill
• 1/2", 5/8" and 3/32" Drill Bits
• 1-1/2" Wood Bit or Metal Hole
Cutter (if metal cabinet is used)
Figure 3
• Saw to cut exhaust opening
(if needed)
• Protective Drop Cloth for product
and range - you may also use
carton for protection
2
Figure 2
Ground
Receptacle
Opening for
Power Cord
• Scissors
• Pencil
• Measure
• Tape