Digital Alert Systems 637 Manual de instruções - Página 14

Procurar online ou descarregar pdf Manual de instruções para Conversor de multimédia Digital Alert Systems 637. Digital Alert Systems 637 16 páginas. Dual tone decoder

Digital Alert Systems 637 Manual de instruções
The hexadecimal rotary switches on the front edge of the 3185E determine each digit in the code
sequence. 0 through D select the corresponding DTMF digit to be decoded. The letter 'E' on the rotary
switch represents the '*' DTMF digit and the letter 'F' on the rotary switch represents the '#' DTMF digit.
As stated before, the 3185E is factory set to decode a 4-digit 'ON' code sequence and a 4-digit 'OFF'
code sequence. The first three digits of the code sequence are the same for 'ON' and 'OFF' commands.
The fourth digit for the 'ON' code sequence is factory set to '*', and the fourth digit for the 'OFF' code
sequence is factory set to '#'.
It is not necessary to power down the 3185E when you are programming the code sequence. The 3185E
program will read the switch settings each time a code sequence is received.
Consult FIGURE 1 on page 4 for location of switches and their designations.
When the 3185E is connected to a DC power source, the Power/Valid Digit LED CR14 on the front edge
of the PC board will be illuminated. This LED indicator will continue to illuminate until a valid DTMF digit
is detected or DC power is removed from the board.
The Valid Sequence LED CR15 will illuminate upon the decoding of a correct DTMF code tone pair in
the proper sequence. Upon the fourth correct digit, the output relay activates and the Relay Output LED
CR13 illuminates.
During the reception of valid DTMF tone pairs in a sequence the 3185E will — after decoding a valid
code number — wait for the next valid code in the sequence. If the time between digits is more than 3
seconds, the 3185E will reset and require that the sequence be sent completely again.

Operating With a 4-Digit Code:

When a 4-digit code sequence is selected on the 3185E the switch program will be as follows:
SWITCH 1 = first digit of the code sequence for both 'ON' and 'OFF'.
SWITCH 2 = second digit of the code sequence for both 'ON' and 'OFF'.
SWITCH 3 = third digit of the code sequence for both 'ON' and 'OFF'.
SWITCH 4 = fourth digit of the code sequence for 'ON' (preset to '*' if switch not installed).
SWITCH 5 = fourth digit of the code sequence for 'OFF' (preset to '#' if switch not installed).
If the 3185E is programmed for momentary relay output or alternating relay action SWITCH 5 is not used
for programming.

CODE SELECTION

OPERATION

14