and seamlessly switches over to the secondary supply, "P2," which is plugged into the second
power jack. The switch-over operation is transparent to the user; continuous operation of the
patchbay is maintained.
Table 1 below describes the possible the states and meanings of the two power indicator LEDs,
"L1" and "L2," which are mounted on the front panel.
Top LED (L1)
(Clear when Off)
Yellow
Yellow
Red
Table 1 – Explanation of the states of the two power indicator LEDs
NOTE: If you experience a power indicator LED color combination that is not listed in Table 2,
then the patchbay may possibly be exhibiting an internal fault. Please call Bittree Customer
Service for further assistance.
If you ordered Model 422A32 with the single power supply, your patchbay will still function but
will not have the benefit of a redundant power supply. Continue reading for information and
instructions pertaining to patchbays with either dual or single power supplies.
The DC power plug of the power supply(s) is equipped with a threaded cowling to ensure that,
once installed, it will stay securely plugged in – even if the power supply cable is accidentally
tugged. After plugging the DC power plug into the DC power jack on the rear panel of the
patchbay, screw the threaded cowling clockwise until finger-tight.
TECHNICAL NOTE: This patchbay employs a special "long" power jack, specifically designed
for use with a 2.0 mm inner-diameter, 12 mm long power plug with a locking threaded cowling.
Standard length 2.1 mm power plugs will not make good contact with this power jack.
The 120 Volt AC power plug of the power supply is a three-prong AC power plug that includes
an earth-ground terminal. Bittree recommends that this AC power plug only be plugged into AC
outlets that have been tested and proven to have a true earth-ground connection. Furthermore, if
you are planning to interconnect and patch between more than one RS422 Active Data Patchbays,
please ensure that all the patchbays are connected to a common earth-ground circuit (e.g., by
plugging them all into the same power strip). This ensures that a common ground potential is
established between the different patchbays and the signals are interpreted correctly.
Page 6 – Bittree RS-422 64-Port Active Data Patchbay User Guide
Bottom LED (L2)
(Green when Off)
Green
Off
Green
All clear. Both power supplies are operational.
The primary power supply has failed. Repair or
replace as soon as possible. Patchbay is powered
from the secondary power supply, but power
redundancy no longer exists.
The secondary power supply has failed. Repair or
replace as soon as possible. Patchbay is powered
from the primary power supply, but power
redundancy no longer exists.
Meaning