2–2 Physical Installation
2.1.4 STI Interconnect Cabling
1. Connect the STI cable(s) to the rear of the SA106 chassis (Figure 2–1).
Each cable is secured with two captive screws. For cabling of the
TA867, see the documentation in the TA867 Kit.
2. Connect the HSC cable(s) to the K.SI module.
K.STI modules do not support the SA106 and TA867 storage
subsystems.
3. Assign a unique unit number to the magazine tape subsystem. The
unit number is a decimal number between 0 and 255. To assign the
unit number, use the push buttons on the side of the unit number
switch to increase or decrease the number.
Transport numbers are always assigned in groups of four to each
formatter. Transports are assigned the following unit numbers:
•
0 to 3 for the first formatter
•
4 to 7 on the second formatter of a system with two or more
formatters
•
8 to 11 on the third formatter, and so on
4. Place a decal identifying the transport unit number just below the
loader fault indicator on the magazine tape subsystem .
2.1.5 STI Cables
The SA106 storage subsystem will contain one, 25-foot STI cable. You will
need a second cable for dual applications.
NOTE