5 Useful information
Table 5-4 Response telegram with no errors
Byte
Value
0
0x0C
0x1C
1
0x00
2
0xC7
3
0x00
4
0x00
5
0xC6
vhl_select: Select a card located in the antenna field of the reader
Table 5-5 Job telegram
Byte
Value
0
0x0C
0x1C
1
0x01
2
0x00
3
0x04
4
0x00
5
0xFF
6
0xFF
7
0x01
8
0x00
9
0xXX
Table 5-6 Response telegram without errors
Byte
Value
0
0x0C
0x1C
1
0x01
2
0x00
3
0x01
4
0x00
5
0x30
6
0x0D
Reading out UID with SIMATIC RF1070R
Article ID: 109780625,
V1.0,
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length (0 bytes)
Optional checksum (when the value "0x1C" is set in byte 0).
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length
Mask for the card type (e.g. 0xFFFF). You can find detailed
information on the card types in manual number \3\.
Reselect
AllowConfig
Optional checksum (when the value "0x1C" is set in byte 0)
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length
Card type
You can find detailed information on the card types in manual number
\3\.
Optional checksum (when the value "0x1C" is set in byte 0).
09/2020
Description
Description
Description
28