Siemens SITRANS WW300 Manual de Instruções - Página 11
Procurar online ou descarregar pdf Manual de Instruções para Equipamento industrial Siemens SITRANS WW300. Siemens SITRANS WW300 28 páginas. Weighfeeders
Também para Siemens SITRANS WW300: Manual de Instruções (42 páginas)
Mechanical installation
Perform a thorough and systematic inspection of containers immediately upon receipt of
your Siemens weighfeeder. The containers are packed to separate each item and provide
protection during shipping.
Do not remove equipment from shipping crates or boxes until you check for
Note:
possible shipping damage. Contact the carrier immediately if damage is noted.
Your weighfeeder has been designed, assembled, and factory tested for your specific
application.
Notes:
•
Refer to the mechanical drawings sent with this manual prior to commencing with
installation.
•
Do NOT remove the tagged load cell shipping bolt(s) until the installation is
complete to prevent load cell damage.
•
Do NOT weld on or near the weighfeeder while the load cell is connected to the
electronic integrator. Damage to the integrator may result if the load cell is not
disconnected from the integrator.
•
Follow a scheduled, preventative maintenance program to ensure optimum
performance and long equipment life.
Installation
Only qualified personnel are authorized to install and operate this equipment.
Note:
Installation shall be in accordance with local regulations, standards and established
safety practices. Read and understand the instructions before installing, operating or
maintaining the equipment.
1.
Align the in-feed section of the weighfeeder with the discharge of the feed device.
Prevent twisting or misalignment that could induce stress on the weighing section.
2.
Securely fasten the unit to a rigid, level structure. Use a level for verification and
shim as necessary. Prevent any twisting of the frame that may affect weighfeeder
performance.
3.
Construct the necessary support framework to provide a sturdy, rigid base. Vibration
isolators are recommended if the location is subject to moderate or heavy vibration.
4.
Check the gear reducer oil level. See the gear reducer manual for further details on
maintenance.
5.
Flexible in-feed connections are REQUIRED for all applications. Flexible discharge
connections are also recommended. The unit is shipped with a gear reducer
breather; install the breather in the appropriate fill hole per the included reducer
manual.
Inlet and discharge will not support load.
Note:
7ML19985MQ01
SITRANS WW300 - OPERATING INSTRUCTIONS
Page 7