16.5 Installation in a tall unit
Observe the installation dimensions and the safety
clearances in a tall unit.
¡ Ensure that the intermediate floor has a gap to the
installation wall in order to ventilate the appliance.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡ Only fit the appliance up to a height which allows
accessories to be easily removed.
16.6 Installing two appliances on top of
each other
Your appliance can also be installed above another ap-
pliance.
16.7 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡ The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to local regulations.
¡ The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡ The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡ Contact protection must be ensured by the installa-
tion.
¡ Only a licensed professional may connect appli-
ances without plugs. They are subject to the require-
ments of the local electricity provider.
Electrically connecting an appliance without a
protective contact plug
Note: Only licensed specialists may connect the appli-
ance. Damage caused by incorrect connection is not
covered under the warranty.
An isolating switch must be integrated into the perman-
ent electrical installation according to the installation
regulations.
Identify the phase and neutral conductors in the
1.
socket.
The appliance may be damaged if it is not connec-
ted correctly.
2.
Only connect the appliance to a mains voltage
between 220 und 240 V.
Connect the wires of the mains power cable accord-
3.
ing to the colour coding:
Green/yellow = Conductor
‒
Blue = Neutral conductor
‒
Brown = Phase (external conductor)
‒
16.8 Installing the appliance
Slide the appliance and centre it.
1.
Do not kink the connection cable.
If necessary, use a tool to remove the cable guide.
2.
Open the oven door completely.
3.
Remove the cover.
4.
Installation instructions en
37