Epson EasyMP EMP-1715 Manual do utilizador
S5/X5/83/822/83+/822+/EX90
G5350/G5300/G5150/G5100/
1735W/1730W/1725/1720
84/85/824/825/826W
Z8000WU/Z8050W
4.2.Power on state (operation indicator is in green)
All commands are executable.

5.Error Status

A projector returns the error status when a projector receives "ERR?" command.
The following projectors can return the error status while the projectors become the cool-downs status at an error and the projectors become
the error status after cooling down.
EMP-1700/1705/1710/1715, 6000/6100/6110/6010, 1815/1810/1825, S5/X5/83/822, 260/280, 400W/410W
EB-G5000/G5100/G5150/G5200W/G5300/G5350
And later models.
[The other models except the above models]
The models except the above models can return the error status while the projectors become the cool-downs status at an error.
The following table shows the return codes and the meaning of error status.
Command
ERR?
ESC/VP21 Command User's Guide for Business Projectors
Model s
62/82
X3(76)
6100/6000
1715/1705
1815/1810/1825
260/280
6110/6010
400W/410W
G5200W/G5000
S6/X6/W6
00
:There is no error or the error is recovered
01
: Fan error
03
: Lamp failure at power on
04
: High internal temperature error
06
: Lamp error
07
: Open Lamp cover door error
08
: Cinema filter error
09
: Electric dual-layered capacitor is disconnected
0A
: Auto iris error
0B
: Subsystem Error
0C
: Low air flow error
0D
: Air filter air flow sensor error
0E
: Power supply unit error (Ballast)
0F
: Shuter error
10
: Cooling system error (peltiert element)
11
: Cooling system error (Pump)
Power Consumption
Network off
about 4.0W
about 5.0W: 230V area
about 0.4W
about 3.8W
about 2.6W
about 4.1W
about 4.1W
about 0.4W
about 4.2W
about 0.4W
about 3W
about 4.0W
about 5.0W
TBD
Returne code
6 of 28
Network on
about 25W
about 23W: 120V area
(only 62/82)
about 10W
about 18W
about 12W
about 5W
(only 83/822)
about 4.1W
(only 280)
about 10.4W
about 4.9W
about 10W
-
about 9.0W
about 12W
TBD