Digital Lighting Systems MF802-12 Manual do utilizador - Página 7

Procurar online ou descarregar pdf Manual do utilizador para Luz de inundação Digital Lighting Systems MF802-12. Digital Lighting Systems MF802-12 12 páginas. 8 channel “mini-fader/ chaser ” cross fader/ color mixing/ animation chaser

Digital Lighting Systems
www.digitallighting.com
MF802-24 0r MF802-12 General Wiring Instructions 24VAC /12VAC
Wiring Notes
0 DO NOT EXCEED 60 W (2.5 Amps. ) per circuit output @ 24VAC. Or 30 W @ 12 VAC
0 MF802 Fader packs may be fed by one 15 (maximum) branch circuits and may have up to four separately switched
loads.
With MF802-24 you may use a single 24 VAC-250 VA or better transformer
.With MF802-12 you may use a single 12 VAC-150 VA or better transformer.
Follow transformer's installation & wiring instructions from manufacturer.
Figure 6 - MF802 Typical 12 VAC or 24 VAC Wiring.
Power inputs to transformers should be on the same phase
12VAC
12 VAC
or
or
24VAC
24VAC
transformer
10 A.
Fuse
MF802-12 or MF802-24
2
Channels 1,2,3,4
1
2
1
S2
-
12302 SW 128th ct, Miami, Fl. 33186 Tel: 305-969-8442 [email protected]
Copyright
2018 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.
C
O
M
1
2 3 4
.
3
SF408
V0.2
For Chasing
Microprocessor
Place jumper
S1
1
MF802
8 channel
12VAC
12 VAC
or
24VAC
24VAC
transformer
10 A.
Fuse
MF802-12 or MF802-24
3
6
4
5
4
5
Ch: 5,6,7,8 control cable
User's Manual - Page 6
16 Pattern
Fader / Chaser
or
5
6 7 8
Channels 5,6,7,8
6
7
1
www.digitallighting.com
1
1
7
8
8