ActronAir ERQ5-21AS Manual de instalação e comissionamento - Página 9

Procurar online ou descarregar pdf Manual de instalação e comissionamento para Acessórios para ar condicionado ActronAir ERQ5-21AS. ActronAir ERQ5-21AS 20 páginas. Esp platinum que split ducted unit - 3 phase

Installation and Commissioning Guide

05. Installation Instructions

The installation instructions provided below are intended as a guide only and do not supersede the relevant council, state and
federal codes, regulations and building code standards. Compliance and consultation with the authorities having jurisdiction
with the installation of this equipment is the responsibility of the installer. ActronAir will not be held liable for any damages or
costs as a result of the installer's failure to comply. Please refer to the matching outdoor unit Installation and Commissioning
Guide for further information and details.

05.01. Lifting the Unit

The installation instructions provided, in Section 06, adhere to WH&S regulations for safe and secure lifting practices in order
to prevent physical injury.
Suggested lifting procedures are outlined in Section 06 as a reference guide to safely lift and transport the unit, however, this
does not over rule the industry WH&S practices.

05.02. Location

This unit is intended for indoor installation only. It is highly recommended that this indoor unit and accessories, particularly
zone barrels, be mounted in the roof cavity.
Mount the unit in a stable and rigid support wherein the weight is properly distributed, such as roof joist and rafters. Take into
consideration the minimum service access clearances provided in the unit drawings.
Locate the indoor unit away from the areas where noise is a critical factor. Use rubber mounting pad (not supplied) in order to
minimize the transfer of noise and vibration into building structures.
A hanging bracket assembly and rubber grommet (optional on other units) are also provided to secure the indoor unit into
the roof rafters. This configuration is most suitable for installations that require the unit to be rigidly secured up from the roof
joist.

05.03. Condensate and Safety

An integrated safety drain tray is provided as a standard inclusion to your indoor unit in order to reduce the potential of
condensate damage to the roof. A drain kit (supplied with some units) is required for the condensate drain to be externally
trapped from the indoor unit. Suggested condensate and safety tray drainage instructions are provided in Section 07 of this
document for your reference.

05.04. Supply Air and Return Air Duct

The indoor unit is supplied with a duct flange as standard in order to facilitate the system's duct connection into the unit.
Supply and return air duct works must be adequately sized to meet the system's air flow and static pressure requirements.
Refer to the unit drawing for supply air and return air duct dimensions, specific to your requirement.
IMPORTANT NOTES TO INSTALLER
Fit a flexible duct connection in between the unit and the duct system, where noise and vibration is a critical consideration.

05.05. Supply Air and Return Air Plenums (Optional)

Supply Air plenums and Duct Plates (twin-spigot) are available in order to facilitate your duct system connection to the indoor
unit. The supply air plenums come in 1-way, 2-way and 3-way options.
ActronAir is constantly seeking ways to improve the design of its products, therefore specifications are subject to change without notice.
ESP Platinum QUE - Three Phase
Copyright © 2019 Actron Engineering Pty. Ltd.
09