Ricoh Rh 100 Manual de Instruções - Página 18
Procurar online ou descarregar pdf Manual de Instruções para Impressora Ricoh Rh 100. Ricoh Rh 100 26 páginas.
Também para Ricoh Rh 100: Manual rápido (4 páginas)
Fixing Ink (Fix
CAUTION:
•
Do not touch the inside of the finisher when you open the front cover.
The surface of the heater will be as high as about 180 °C (356 °F).
•
Especially never touch the black heater on the upper part of the inside
of the machine.
•
When taking a T-shirt out of the cassette after a print image has been
fixed to it, do not touch the front side or metal plate (black) on the back
side of the casette's table because it is hotter than 100 ° C (212 °F ).
•
If children use this machine, their parents must be with them and
they should be very careful in using this machine. Otherwise, injury or
burns may result.
•
Default settings are as follows:
•
Temperature: "High" (170 °C, 338°F)
•
Fixing Time: "Medium" (3 minutes)
•
Ink might not fix properly or fabric color might change depending on usage
conditions. After checking for the garment you use, set the temperature and
time.
•
Before installing the cassette to the finisher, do not spray any liquid on the
fabric or cassette. If you heat a wet cloth or cassette in the finisher, the color of
the cassette table may stain the back side of the fabric.
•
You can unlock the front cover manually if the power is shut off due to a
power failure or other causes while the front cover is locked. Insert a piece of
cardboard or a card between the front cover and the operation panel and slide
it from the right to the left as you pull the front cover towards you.
18
)
DSA145