Service and maintenance
————————————————————————————————–
Although the frequency of appliance servicing and
maintenance will depend on use and the type of instal-
lation, a qualified service technician should perform an
appliance check-up annual.
Storage of an appliance indoors is permissible only if
the cylinder is disconnected and removed from the ap-
pliance.
The use of a coorderinating burner cover and protective cover
during the off season is highly recommended to keep your table
and burner looking new and ensuring extended trouble-free
operation.
!
WARNING
Risk of injury or property damage
Before servicing
• Turn off utilities to appliance.
• Ensure appliance is completely cooled
Maintenance and Service Tasks
For service calls: Contact the store your product was purchased from first. Contact CabanaCoast at 1-855-
502-9988 if further assistance is needed.
Inspect
Burner Assembly
Burner Ignition and Operation
Gas Hose with Regulator
Maintenance Tasks
Remove decorative glass and examine burner. Vacuum and
1
wipe out as needed. Use caution when cleaning these areas
Inspect for warping and corrosion. Repair as necessary
2
Check the hose connecting the LP gas cylinder to ensure it is
3
not damaged. Replace as necessary.
4
Verify air shutter area is clean
1
Verify all gas connections are tight and leak-free
Clean burner top, inspect for plugged ports, corrosion, or de-
2
terioration. Replace burner if necessary.
3
Inspect for flame problems.
Verify air shutter is clear of dust and debris and is in correct
4
position for the gas type being used.
5
Inspect orifice for soot, dirt, or corrosion
Verify manifold and inlet pressures. Adjust regulator as re-
6
quired.
The gas hose with regulator supplied with appliance must be
1
used for LP installations. The replacement must be those spec-
ified by the appliance manufacturer
!
WARNING
Annual inspection by qualified tech-
nician recommended.
Check:
• Obstructions of combustion and ven-
tilation air.
• Condition of burner assembly
• burner air shutter adjustment.
• Gas connections and fittings
Risk of:
• Fire.
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors
17