RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None
= Input Number
x
There is either a period (.) at the end of many commands. This character
must be present for the command to process correctly.
A carriage return and line feed will follow all responses.
Description
Switch to x input
Turn off audio and video output
and lock Source button.
Turn on audio and video output
and unlock Source button.
Turn on auto switch mode
Turn on manual switch mode
Turn on ARC
Turn off ARC
Get system status: current source,
switch mode, and ARC mode
RS232 Control
Command
xB1.
0B0.
0B2.
601%
602%
ARC1&
ARC0&
600%
Response
AV: x -> 1
MUTE
UNMUTE
Auto Switch
Manual Switch
Audio Return System
Switch Device System
AND
AV: x -> 1
MUTE OR
UNMUTE AND
Auto Switch OR
Manual Switch AND
Audio Return System OR
Switch Device System