Argo 387006118 Dados técnicos e manual de serviço - Página 10

Procurar online ou descarregar pdf Dados técnicos e manual de serviço para Ar condicionado Argo 387006118. Argo 387006118 19 páginas. Indoor unit, split system air conditioner

■ HIGH POWER
Raises the power but remains in the same operating mode.
This function is set with the HIGH POWER button on the remote
controller.
(It is set regardless of the temperature and fan speed settings.)
● HIGH POWER operation from the remote controller
The unit operates at maximum output for 15 minutes,
regardless of the desired temperature.
The fan speed is 1 step above "High."
Frequency
MAX
0
15 min.
Start
NOTE
• When HIGH POWER operation ends, the unit operates at low
Hz for 5 minutes, regardless of the thermostat OFF conditions.
• When in DRY mode, operation is in the cooling zone.
• When in HEAT mode, defrosting does not occur during HIGH
POWER operation.
• If HIGH POWER is set while defrosting is in progress, HIGH
POWER operation begins after defrosting ends.
• HIGH POWER operation cannot be set from the remote
controller when the unit is stopped.
• HIGH POWER operation and ECONOMY operation cannot be
used at the same time. The function set last takes priority.
■ ECONOMY
• When ECONOMY operation is set, the temperature and fan
speed settings will be adjusted automatically to allow
comfortable sleep.
• When ECONOMY operation is set, "
remote controller.
● COOL and DRY modes
• The indoor unit fan speed is automatically lowered for quiet
operation.
• The temperature setting is raised by 1°C one hour after
ECONOMY operation is set.
● HEAT mode
• The indoor unit and outdoor unit fan speeds are
automatically lowered for quiet operation.
• The temperature setting is lowered by 3°C one hour after
ECONOMY operation is set.
In addition, the temperature setting is lowered by 4°C after
two hours have passed.
Time
5 min.
End
mark" appears on the
■ Lamp colors
Operation lamp
HEAT operation : Red
DRY operation : Orange
COOL operation : Green
TIMER lamp
■ ON timer operation
• Operation starts when the time set for the ON timer is reached.
When a time is set, the TIMER lamp illuminates.
• The below comfort timer programming is performed.
A comfort time is calculated from the set temperature and the
room temperature, either 60 minutes prior or 30 minutes prior to
the set ON timer time, and operation is started in advance of
the set ON time. (The indoor fan speed is "Medium.")
[COOL]
Indoor temperature – Set temperature = Temperature difference
[HEAT]
Set temperature – Indoor temperature = Temperature difference
Temperature difference (°C)
12 < Temperature difference
6 < Temperature difference
NOTE
This function does not operate if the ON timer standby time is
less than 30 minutes.
■ OFF timer operation
• Operation stops when the time set for the OFF timer is
reached.
When a time is set, the TIMER lamp illuminates.
■ Timer backup
• If the indoor unit is unable to receive the timer time-end signal
when the ON or OFF time is reached, then timer time-end
occurs according to the indoor unit backup timer within
approximately 26 minutes.
• Operation stops if there are no operator controls for 25 hours or
longer after unit operation switched from OFF to ON by use of
ON timer operation.
10
: Green
Advance start time (min.)
60
30