Argo DADOS XL Manual de Instruções - Página 5

Procurar online ou descarregar pdf Manual de Instruções para Ar condicionado Argo DADOS XL. Argo DADOS XL 11 páginas. Local air conditioner

Argo DADOS XL Manual de Instruções
This appliance can be used to Cool, Dehumidify, Fan and Heat. In changing from one mode to another, the fan continues
operating but the compressor stops; the compressor starts up again 3 and a half minutes later. This delay in start-up
protects the compressor from any damages.
IMPORTANT!
To operate in Cooling, Dehumidifying and Fan mode, the air-conditioner must be positioned with the air outlet fitted with
deflectors positioned to the front.
To operate in Heating mode, the appliance must be rotated 180º so as to have the air outlet without deflectors to the front;
using the remote control or Power switch on the control panel, select the Heating mode (see the chapter entitled
OPERATION).
Cooling, Heating and Fan
THE DISCHARGE TUBE MUST BE CONNECTED to the appliance AT ALL TIMES: the only exception is when the
appliance is used for Dehumidification only, in which case it is recommended that the appliance discharges
directly into the environment to obtain maximum efficiency (see the paragraph entitled "Dehumidification Mode").
Clean the air filters under the easily removable side panels regularly to keep the air-conditioner working efficiently.
1. COOLING MODE
 The first time it is turned on, the air-conditioner will operate in Cooling mode with the temperature set to 25ºC by
default.
 The temperature can be adjusted between 17° and 30°C.
 In this way, each time the Power button is pressed, the unit switches off, the appliance saves the temperature set
and when switched back on again, it will retain this setting.
 In this way, fan speed can be adjusted, the Timer, ECO function can be set.
2. DEHUMIDIFICATION MODE
Press FUNCT to select Dehumidification until the relevant icon appears.
The temperature is controlled by the electronic card and cannot be regulated.
In this way, each time the Power button is pressed, the unit switches off, the appliance saves the settings and when
switched back on again, it will retain them.
Fan speed is fixed to low and cannot be adjusted.
NOTE
The air-conditioner does not cool the environment when operating as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible hose must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into
the environment.
Dehumidification mode is recommended in autumn and winter.
If used in the summer, it is best to leave the flexible hose attached, in order to send the hot air outside rather
than releasing it into the environment.
During dehumidification, it is best to ensure continuous drainage (see paragraph entitled "HOW TO ELIMINATE
CONDENSATION").
V 07/13

HOW TO USE THE APPLIANCE

OPERATING MODES

Dehumidifying
5