Sony BVP-E30 series Manual - Página 7

Procurar online ou descarregar pdf Manual para Câmara de vídeo Sony BVP-E30 series. Sony BVP-E30 series 34 páginas. Sdtv portable cameras
Também para Sony BVP-E30 series: Manual de operação (36 páginas), Brochura e especificações (14 páginas), Manual de operação (38 páginas)

Sony BVP-E30 series Manual
MCS mode
The MCS mode enables confi guration of the multiple camera systems consisting of the multiple equipment supporting the
network connection. The MCS mode is equivalent to the conventional system that uses CNU. Cameras can be selected from
the MSU enabling control and the RCP assignment. In the MSU mode, any single MSU among the equipment in the system
should be assigned as the Master and be set accordingly.
Connection mode
The connection modes are the sub modes of the Bridge mode determining operations of the Bridge mode. The connection
mode is set by the panel equipment side determining confi guration. There are following three connection modes. Use
Semi-Auto mode normally.
Active :
The settings that are required for connection are performed to the target equipment from one's own side. (The
target equipment to be connected is called Target.)
In this mode, one side should be set as Active while the other side should be set as Passive.
Passive :
The equipment of Passive mode awaits connection from the Target equipment in this mode. (Camera and CCU/
HDCU are fi xed to Passive so that no setting is required.)
When the Passive mode is used, the system camera equipment that does not support the network function of
the camera network system can be controlled via network. (However, the equipment that does not guarantee
connection with RCP or MSU can not be connected.)
Since the Bridge mode is confi gured on the premise of one-to-one connection of equipment, the connection
that allows a single equipment to become Target of multiple units of equipment is not possible.
Semi-Auto : When equipment is set in the Semi-Auto mode, the equipment is switched to Active or Passive depending on
the connection environment. When RCP or MSU is connected to network as standalone equipment indepen-
dently, they become Active. When RPC or MSU is connected to CCU/HDCU or camera with the CCA-5 cable,
they become Passive. (Factory default setting)
Network setting should be made in each equipment. For the equipment of Active mode, IP address of the Target equipment
should also be set.
Master/Client
When the MCS mode is selected to confi gure a system, a single equipment of the system should be set as Master.
This equipment is called Master, and other equipment is called Client. (Only MSU can be set as Master.)
When multiple units of MSU are used, a single MSU should be set as Master while all other units of MSU should be set as
Client. The Master equipment performs the function equivalent to CNU in the conventional system. Since the Master equip-
ment performs the system arbitration, never turn off the power of the Master equipment while the system is in operation.
The network setting (including IP address, subnet mask and default gateway) and the equipment number (CCU/HDCU
number, RCP number and MSU number) should be set to each equipment. The IP address of the Master equipment should
be set in the Client equipment separately.
RCP assignment
The RCP assignment is the function that enables us to change combination of camera and CCU/HDCU without changing
the physical connection of the control cable, for the control from RCP. The RCP assignment function can be used in the
MCS mode.
Preview
The RCP of the Joystick (lever) type has the Preview switch. ON/OFF status of the Preview switch can be obtained from
the interface connector.
Camera Network System
1-3 (E)