Specifying frame rate

The frame rate of the video output can be specified in the free-run operation. The value of the frame rate [fps] ×
1,000,000 should be entered. The frame rate faster than the fastest frame rate cannot be set.
Command
FRAMERATE
62500 to 30000000 to *
* The upper limit varies depending on the partial scan setting.
Example for setting 15 [fps]: FRAMERATE 15000000

Displaying frame rate

The current frame rate during the auto frame rate operation is displayed.
Command
FRAMERATE-ACTUAL

Fastest frame rate for partial scanning

The fastest frame rate varies depending on HEIGHT for partial scanning.
BASE-CLOCK:75MHz/45MHz
1600
1400
1200
1000
800
600
400
200
Parameter
26
75 MHz 3tap, Bit=8
75 MHz 2tap, Bit=8/10/12
45 MHz 1tap, Bit=8/10/12
45 MHz 2tap, Bit=8/10/12
75 MHz 1tap, Bit=8/10/12
45 MHz 3tap, Bit=8