Sony XCU-CG160 Manual técnico - Página 23

Procurar online ou descarregar pdf Manual técnico para Câmara digital Sony XCU-CG160. Sony XCU-CG160 45 páginas. Digital video camera module

Sony XCU-CG160 Manual técnico

Trigger overlap

Set TriggerFastMode to False.
Trigger signals can be accepted during the interval that sensor readout signals are asserted.
If the trigger cycle exceeds the maximum value of the frame rate, images are distorted.
When trigger overlap is allowed (when TriggerFastMode is False)
Trigger signal
Exposure signal
Sensor readout signal
(sensor output)
When trigger overlap is inhibited (when TriggerFastMode is True)
Trigger signal
Exposure signal
Sensor readout signal
(sensor output)
Trigger input inhibited
(frame rate maximum value)
Exposure time
Trigger input inhibited
(exposure time + sensor readout time)
Exposure time
23