DIGITIZE System 3505 Manual de instalação e operação - Página 10
Procurar online ou descarregar pdf Manual de instalação e operação para Servidor DIGITIZE System 3505. DIGITIZE System 3505 20 páginas. Remote alarm terminal option
Também para DIGITIZE System 3505: Manual de operação (12 páginas)
You should activate the daily test following either a restart of the SYSTEM 3505, or if
the data line between the SYSTEM 3505 and the Monaco D-700/7000 has been
disconnected for a period of time.
Whether initiate automatically or manually the following will be printed on activation of
a daily test request.
1.8
AUTO LOAD OF BT-2 BOXES
The SYSTEM 3505 will auto load all the BT-2 Boxes into its non-volatile memory
whenever it is initially powered up and a Daily test is requested. When the BT-2 boxes
are loaded into the SYSTEM 3505, all the BT-2 units are placed in the "Active" mode. If
any boxes are Disabled, you need to go to the 3 6 SET menu and Disable the non-active
BT-2 units. See the section on the 3 6 SET menu.
If you install a new or spare SYSTEM 3505 unit, you will need to purge the BT-2 list in
the new unit, so it will auto load the field BT boxes. You can enter the boxes one by one
into the SYSTEM 3505 via the 3 6 SET menu.
1.9
ADD/CHANGE BT-2 UNITS
To bring up the Monaco D-500/700 SET menu, press 3 6 then the SET key. The display
will be as follows:
DIGITIZE, INC. 700270 REV A 01/06
Specifications Subject to Change Without Notice
1-5