ACU-RITE SENC 150 Manual de instalação - Página 3

Procurar online ou descarregar pdf Manual de instalação para Conversor de multimédia ACU-RITE SENC 150. ACU-RITE SENC 150 6 páginas. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Também para ACU-RITE SENC 150: Manual de instalação (8 páginas), Manual de referência (20 páginas), Manual de instalação (4 páginas), Manual de instruções (12 páginas)

SENC 150
Center support
Align the center of the scale case to within .010" to
the ends, and transfer punch the support hole
location.
Remove the center support, drill and tap the hole
location for an 8-32 x 1/2" deep.
Attach the center support to the scale case and
table. Align the center of the scale case with each
end to within .010" and secure in place.
Reading head installation ...
*8-32 x 5/8" SHCS (2)
A gap will exist between
bracket and reading head.
Insert the two *8-32 x 5/8" SHCS. Insure the
bracket is adjusted to provide proper screw head
clearance. Do not tighten screws at this time.
Set each leveling set screw by placing a .001" - .003"
feeler gage between the set screw and the bracket.
Adjust each set screw until a slight drag is felt on
the feeler gage.
Evenly tighten the two 8-32 SHCS.
Installation Manual 385033-000
8-32 x 3/4" SHCS
*Leveling set screw (3)
Acu-Rite Companies Inc.
One Precision Way • Jamestown, NY 14701
Encoder Installation Manual For: Bridgeport Series I
Vertical Knee Mill / Longitudinal X Axis front table mount
Encoder button up ...
Use allen wrench from set screw adjustment to
slide alignment brackets away from the reading
head.
Remove alignment brackets and save.
Move the axis through its full travel. Confirm that
the assembly does not interfere with the machine
movement.
Proceed with the Cross
Feed installation
3
Slide brackets back
away from the
reading head and
cable
Twist brackets
45° to remove
P.N. 385033-121 Ed C 2/06