Argo-Hytos TSE3-D Manual de Instruções
Procurar online ou descarregar pdf Manual de Instruções para Interruptor Argo-Hytos TSE3-D. Argo-Hytos TSE3-D 12 páginas. Electronic pressure switch
Operating instructions - Electronic pressure switch
TSE3-D
Contents
1 Preliminary note ............................................................................................................................................ 1
1.1 Symbols used ........................................................................................................................................... 1
2 Safety instructions ........................................................................................................................................ 1
3 Functions and features .................................................................................................................................. 2
3.1 Applications ............................................................................................................................................. 2
4 Function ......................................................................................................................................................... 2
4.1 Communication, parameter setting, evaluation ................................................................................... 2
4.2 Switching function .................................................................................................................................. 2
4.3 Analogue function .................................................................................................................................. 3
4.4 IO-Link ...................................................................................................................................................... 3
5 Installation ..................................................................................................................................................... 3
6 Electrical connection ..................................................................................................................................... 4
7 Operating and display elements .................................................................................................................. 4
8 Menu .............................................................................................................................................................. 5
8.1 Menu structure: main menu ................................................................................................................... 5
8.2 Explanation of the menu ........................................................................................................................ 5
8.2.1 Explanation of the menu level 1 ....................................................................................................... 5
8.2.2 Explanation of the menu level 2 ....................................................................................................... 6
9 Parameter setting ......................................................................................................................................... 6
9.1 Parameter setting in general ................................................................................................................. 6
9.2 Configure display (optional) .................................................................................................................. 8
9.3 Set output signals ................................................................................................................................... 8
9.3.1 Set output functions .......................................................................................................................... 8
9.3.2 Define switching limits for the hysteresis function ........................................................................ 8
9.3.3 Define switching limits for the window function ........................................................................... 8
9.3.4 Scaling of the analogue value .......................................................................................................... 8
9.4 User settings (optional) .......................................................................................................................... 9
9.4.1 Set delay for the switching outputs ................................................................................................. 9
9.4.2 Set output logic for the switching outputs ..................................................................................... 9
9.4.3 Set damping for the switching signal .............................................................................................. 9
9.4.4 Damping for analogue output .......................................................................................................... 9
9.4.5 Zero-point calibration ........................................................................................................................ 9
9.4.6 Read min/max values for the system pressure ................................................................................ 9
9.4.7 Reset all parameters to factory setting ............................................................................................ 9
9.4.8 Set colour change of the display ...................................................................................................... 9
9.4.9 Graphical depiction of the colour change of the display ..............................................................10
10 Operation ..................................................................................................................................................11
10.1 Read set parameters ...........................................................................................................................11
10.2 Self-diagnosis / error indications .......................................................................................................11
11 Technical data and scale drawing ............................................................................................................12
11.1 Setting ranges .....................................................................................................................................12
11.2 Further technical data .........................................................................................................................12
12 Factory setting ..........................................................................................................................................12
1 Preliminary note
Symbols used
1.1
►
Instructions
>
Reaction, result
[...]
Designation of keys, buttons or indications
→
Cross-reference
Important note
Non-compliance may result in malfunction or interference
Information
Supplementary note
2 Functions and features
› Please read this document prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions.
› If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur.
› Check the compatibility of the product materials with the media to be measured in all applications.
› Correct condition of the device for the operating time can only be guaranteed if the device is only used for media to which the wetted
materials are sufficiently resistant → 3.1 Applications.
The responsibility whether the measurement device is suitable for the respective application lies with the operator.
The manufacturer assumes no liability for consequences of misuse by the operator.
Improper installation and use of the devices result in a loss of the warranty claims.
Page 1
More information at www.argo-hytos.com
Subject to change · TSE3-D_9193_1en_09/2019