Cisco Firepower 4110 Manual de manutenção e atualização - Página 14
Procurar online ou descarregar pdf Manual de manutenção e atualização para Hardware de rede Cisco Firepower 4110. Cisco Firepower 4110 20 páginas. Rack-mount and ground the chassis
Também para Cisco Firepower 4110: Manual (36 páginas), Manual (26 páginas), Manual (8 páginas), Manual (42 páginas), Começar a trabalhar (42 páginas)
Connect the DC Power Supply Module
Figure 6: Remove the Plastic Cover
Step 5
To prevent any contact with metal lead on the ground wire and the plastic cover, you must wrap the positive and negative
lead cables with sleeving. Insulate the lug with shrink sleeving for each lead wire if using noninsulated crimp terminals.
Sleeving is not required for insulated terminals.
Step 6
Remove the two M5 screws.
Figure 7: Remove the M5 Screws
Step 7
For easier cable management, insert the negative lead cable first. Replace the grounding lug with the cable in the
following order—wire terminal, then the screw with the captive washer.
Maintenance and Upgrade
14
Maintenance and Upgrade