Cisco SNS-3415 series Manual de instalação - Página 36

Procurar online ou descarregar pdf Manual de instalação para Servidor Cisco SNS-3415 series. Cisco SNS-3415 series 36 páginas. Sns-3400 series
Também para Cisco SNS-3415 series: Manual de instalação (19 páginas), Manual de resolução de problemas (8 páginas)

Cisco SNS-3415 series Manual de instalação
Setup CIMC Configuration Utility
Step 4
Set the NIC mode to your choice for which ports to use to access the CIMC for server management (see
or 3495 Appliance Front Panel View, on page 3
• Dedicated—The 1-Gb Ethernet management port is used to access the CIMC. You must select NIC redundancy
None and select IP settings.
• Shared LOM (default)—The two 1-Gb Ethernet ports are used to access the CIMC. This is the factory default
setting, along with Active-active NIC redundancy and DHCP enabled.
• Cisco Card—The ports on an installed Cisco UCS P81E VIC are used to access the CIMC. You must select a NIC
redundancy and IP setting.
The Cisco Card NIC mode is currently supported only with a Cisco UCS P81E VIC (N2XX-ACPCI01) that is
Note
installed in PCIe slot 1.
Step 5
Use this utility to change the NIC redundancy to your preference. This server has three possible NIC redundancy settings:
• None—The Ethernet ports operate independently and do not fail over if there is a problem.
• Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
• Active-active—All Ethernet ports are utilized simultaneously.
Step 6
Choose whether to enable DHCP for dynamic network settings, or to enter static network settings.
Note: Before you enable DHCP, your DHCP server must be preconfigured with the range of MAC addresses
Note
for this server. The MAC address is printed on a label on the rear of the server. This server has a range of six
MAC addresses assigned to the CIMC. The MAC address printed on the label is the beginning of the range of
six contiguous MAC addresses.
Step 7
(Optional) Use this utility to make VLAN settings.
Step 8
Use this utility to set a default CIMC user password.
Changes to the settings take effect after approximately 45 seconds. Refresh with F5 and wait until the new
Note
settings appear before you reboot the server in the next step.
Step 9
Press F10 to save your settings and reboot the server.
Note: If you chose to enable DHCP, the dynamically assigned IP and MAC addresses are displayed on the
Note
console screen during bootup.
Note
By default, the baud rate of the serial port is set to 115200. After you configure CIMC, log in to the CIMC
user interface and change the serial port buad rate to 9600.
Cisco SNS-3400 Series Appliance Hardware Installation Guide
32
Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances
for identification of the ports):
Cisco SNS-3415