Cisco UCS B200 M4 Manual de manutenção - Página 8

Procurar online ou descarregar pdf Manual de manutenção para Servidor Cisco UCS B200 M4. Cisco UCS B200 M4 24 páginas. For e5-2600 v4 series cpus
Também para Cisco UCS B200 M4: Nota de instalação e manutenção (30 páginas), Nota de instalação e manutenção (46 páginas), Upgrade Manual (9 páginas)

Cisco UCS B200 M4 Manual de manutenção

Installing the FlexStorage Module

Figure 5: Location of the Motherboard CMOS Battery
Installing the FlexStorage Module
The Cisco UCS B200 M4 blade server uses an optional Cisco UCS FlexStoarge modular storage subsystem
that can provide support for two drive bays and RAID controller or NVMe-based PCIe SSD support
functionality.
Procedure
Step 1
Place the FlexStorage module over the two standoff posts on the motherboard at the front of the server.
Step 2
Press down on the drive bay cage where it is labeled "Press Here to Install" until the FlexStorage module
clicks into place.
Servicing a Blade Server
8
Servicing a Blade Server