Cisco UCS B260 M4 Nota de instalação e manutenção - Página 34

Procurar online ou descarregar pdf Nota de instalação e manutenção para Servidor Cisco UCS B260 M4. Cisco UCS B260 M4 46 páginas. Blade server
Também para Cisco UCS B260 M4: Nota de instalação e manutenção (50 páginas)

Cisco UCS B260 M4 Nota de instalação e manutenção
Servicing the Blade Server

Channels

CPUs. DIMMs installed in slots for an absent CPU will not be recognized. For optimal performance, distribute
DIMMs evenly across all CPUs. DIMM connector latches are color coded blue, black, and white/ivory, and
we recommend that you install the DIMMs in that order.
An absent CPU is not a supported configuration.
Note
Figure 19: Memory Slots Within the Blade Server
1
DIMMs for CPU 1
2
DIMMs for CPU 2
Channels
Each CPU has 8 channels, consisting of 3 DIMMs. Each channel is identified by a letter. Each channel member
is identified by numbers, 1, 2, or 3.
Install DIMMs according to the configuration in the following table.
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v4 CPUs
26