When Placing the Reducer Into Service:
1.
Assemble the vent plug into the proper hole.
2.
Clean the shaft extensions with petroleum solvents.
3.
Fill the unit to the proper oil level using a recommended
lubricant. VCI oil will not affect the new lubricant.
4.
Follow the installation instructions provided in this manual.
Table 4 - Quantity of VIC #105 Oil
Case Size
(H)SCXT105
(H)SCXT205
(H)SCXT305A
(H)SCXT405A
(H)SCXT505A
(H)SCXT605
(H)SCXT705
VCI #105 & #10 are interchangeable.
VCI #105 is more readily available.
Quarts or Liters
.1
.1
.1
.2
.3
.4
.5
5