Epson EMP Monitor Manual de operação - Página 31
Procurar online ou descarregar pdf Manual de operação para Software Epson EMP Monitor. Epson EMP Monitor 37 páginas. Emp monitor for projectors
Também para Epson EMP Monitor: Manual de operação (11 páginas), Manual de instruções (12 páginas), Manual do utilizador (42 páginas), Manual de operação (34 páginas), Manual de operação (14 páginas)
E-mail notification function settings
The mail notification function can be used to send corresponding
notification messages to a preset e-mail address when a projector that is
connected to the network assumes a certain status, or if it experiences a
problem or warning. By using this function, the operator can be
notified of a projector's status or problems even when the operator is
in a different location from the projectors.
• Up to three addressees (destinations) can be registered and
q
messages can be sent to all of them at once.
• If a critical problem develops with a projector which causes it to
suddenly stop working, it may not be possible for the projector
to send a message notifying an operator of the problem.
• If Standby Mode is set to Network ON or Network Monitoring
is set to ON in the projector configuration menus, you can
monitor the projector even when it is in standby mode (when its
power is turned off). s Projector's User's Guide
• On some projectors, the mail notification function can be set in
the configuration menu. When notification messages are set to be
sent in the projector's configuration menu, both the settings in
the configuration menu and settings made on EMP Monitor are
functional.
• Detectable status with the mail notification function differs with
the projector you are using.
Procedure
A
Select "Mail notification function" from the Tool menu.
B
The Set mail notification function window will be displayed.
Make the necessary settings while referring to the table below.
Set to ON to use the mail notification function.
Mail notification
function
SMTP server IP
Enter the IP address of the SMTP server. Up to a
address
maximum of 255 bytes can be entered.
When you change a port number of the SMTP
server, specify this port number. The default value is
"25".
You can enter a valid number from 1 to 65535.
Enter the sender's e-mail address. Up to a maximum
Sender mail address
of 255 bytes can be entered.
Specify the destination addresses for the notification
Recipient mail
e-mail. Up to three destinations can be set. Up to a
address 1
maximum of 255 bytes can be entered.
Recipient mail
address 2
Recipient mail
address 3
31