3-7 Trouble shooting
Malfunction status
1.No action after power on.
2.F1 or F2 fuse break indicator bright.
3.Display "
4.Display "
5.No display PV normally or PV unstable.
6.In the normal operation, the temperature
cannot rise up.
7.Temperature control is unstable.
"
"
Check item
TC5E is installed properly?
Power wiring is correct?
Main power switch is malfunction?
TC5E module is malfunction?
Change the fuse accord with the brightly
indicator.
TC5E is installed properly?
Thermocouple is break?
Extension cable is loose or breaks?
TC5E module is malfunction?
Thermocouple is reverse?
TC5E module is malfunction?
Refer item 3.
Power leakage?
The ground is properly?
TC5E is installed properly?
Extension cable is loose or breaks?
Heater is malfunction?
TC5E(TRIAC) is malfunction?
Refer 1-4-5, execute PID self-tuning.