Eci Telecom Ribbon SBC 7000 Montagem - Página 2
Procurar online ou descarregar pdf Montagem para Ventilador Eci Telecom Ribbon SBC 7000. Eci Telecom Ribbon SBC 7000 4 páginas.
5.
Figure 2: Removing the Fan Assembly
Whenever a Fan Assembly is nonfunctional or removed, the speed of the three remaining Fan Assemblies increases to
compensate for the missing fan.
6.
Insert the new Fan Assembly to the same position.
7.
Tighten the captive fastener to 6 in-lb using the torque driver.
8.
Verify that the Fan Status LED is green. The LED is at the right hand bottom of the Fan Assembly.
Figure 3: Fan Assembly status indicator
9.
Remove the ESD wrist strap from the chassis.
10.
Reinstall the front panel bezel.
11.
From the application, verify that the Fan Failure alarms are not generated.
12.
Verify that the fan failure LED on the front panel is
CRU Storage
Confidential and Proprietary. Copyright © 2020-2021 Ribbon Communications Operating Company, Inc. (''Ribbon''). © 2020-2021 ECI Telecom Ltd.
OFF
.
Page 2