Dimplex 30" FIREPLACE Manual de instruções de instalação e funcionamento - Página 10
Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Aquecedor Dimplex 30" FIREPLACE. Dimplex 30" FIREPLACE 12 páginas. Thermocomfort mechanic storage heater
Também para Dimplex 30" FIREPLACE: Manual do utilizador (16 páginas)
Start-Up, Technical Device Information
Reassembly
If devices which were already installed and operated are
dismantled and reassembled in another place, they, too,
must be started-up according to the above instructions after
installation. During installation please ensure that the
thermal insulation is not damaged. Damaged parts of the
thermal insulation must be replaced.
Repair Notice
!WARNING!
The product contains both a high voltage supply circuit and a
high voltage control circuit. Ensure both circuits have been
isolated before opening the enclosure.
Electric storage heaters may only be repaired by qualified
personnel. Repairs which are improperly carried out can
endanger the safety of the user.
The devices have a high-grade thermal insulation. Only
remove the core room cover with integrated thermal
insulation when replcaing the heating elements. All other
electrical components can be accessed by removing the side
panels.
Technical Device Information
Designation
Brick bundles
VFMQ 20
4 x 25
VFMQ 30
6 x 25
VFMQ 40
8 x 25
VFMQ 50
10 x 25
VFMQ 60
12 x 25
VFMQ 70
14 x 25
Subject to technical changes
10
Heating
Nominal
element set
power
HFi 212
1.02/1.36 kW
HFi 216
1.31/1.74 kW
HFi 220
1.64/2.18 kW
HFi 227
2.21/2.94 kW
HFi 318
1.51/2.01 kW
HFi 324
1.96/2.61 kW
HFi 330
2.45/3.27 kW
HFi 340
3.27/4.36 kW
HFi 425
2.04/2.72 kW
HFi 432
2.62/3.48 kW
HFi 440
3.27/4.36 kW
HFi 452
4.25/5.66 kW
HFi 540
3.27/4.36 kW
HFi 550
4.09/5.44 kW
HFi 564
5.23/6.97 kW
HFi 648
3.93/5.23 kW
HFi 660
4.91/6.53 kW
HFi 676
6.22/8.28 kW
HFi 756
4.58/6.10 kW
HFi 770
5.72/7.62 kW
HFi 790
7.36/9.80 kW
Resetting the Temperature Limiter
Note on Disposal
Do not dispose of the unit with general household
waste. The device must be taken to a local waste
disposal plant.
Nominal
Nominal
voltage
charging
L1/L2/GND
~208/240V
16 kWh
60Hz
L1/L2/GND
~208/240V
24 kWh
60Hz
L1/L2/GND
~208/240V
32 kWh
60Hz
L1/L2/GND
~208/240V
40 kWh
60Hz
L1/L2/GND
~208/240V
48 kWh
60Hz
L1/L2/GND
~208/240V
56 kWh
60Hz
Weight
Transport
Dimensions
weight
W x H x D
24 5/8" x 26 1/2"
216 lbs
75 lbs
98 kg
34 kg
626 x 672 x 250
30 1/2" x 26 1/2"
301 lbs
88 lbs
137 kg
40 kg
776 x 672 x 250
36 1/2" x 26 1/2"
387 lbs
101 lbs
176 kg
46 kg
926 x 672 x 250
42 3/8" x 26 1/2"
473 lbs
114 lbs
215 kg
52 kg
1076 x 672 x 250
48 1/4" x 26 1/2"
559 lbs
128 lbs
254 kg
58 kg
1226 x 672 x 250
54 1/4" x 26 1/2"
645 lbs
141 lbs
293 kg
64 kg
1376 x 672 x 250
English
x 9 7/8"
mm
x 9 7/8"
mm
x 9 7/8"
mm
x 9 7/8"
mm
x 9 7/8"
mm
x 9 7/8"
mm