CRU Rax 2-BAY RAX215-QR Manual do utilizador - Página 8
Procurar online ou descarregar pdf Manual do utilizador para Armazenamento CRU Rax 2-BAY RAX215-QR. CRU Rax 2-BAY RAX215-QR 13 páginas.
CRU
7. Buzzer and Temperature Configuration
If you would like to set a password for security, enable or disable audible alarms, or change the
temperature thresholds for heat warnings and alarms, you may do so using a free software utility known
as Configurator. To download the Configurator software and user manual, please visit
http://www.wiebetech.com/software/configurator.php. WiebeTech is a brand of CRU.
7.1 Configuration PIN
This feature allows you to set a PIN to prevent unauthorized
configuration. The default PIN is 0000. RAX QR only requires
you to enter a PIN if a different value has been set.
7.2 Buzzers
Place a check in the boxes to indicate which warning/alarm
buzzers you want to be activated.
7.3 System Warning Buzzer
This buzzer will sound when a drive reaches a default
temperature, or a temperature that you set (see section 6.7). As
a visual alert, the "system" LED will glow amber when the
temperature is reached.
7.4 System Alarm Buzzer
This buzzer will sound on 3 occasions:
•
When a drive reaches a default temperature or temperature that you set (see section 7.7).
•
When the enclosure reaches a default temperature or temperature that you set (see section 7.7).
•
When the RAX fan fails.
As a visual alert, the "system" LED on your RAX will glow red when any of these three situations occur.
7.5 RAID Warning Buzzer
This buzzer will sound when RAX QR is in degraded RAID mode (a drive has failed and is in need of
rebuild or the RAID is rebuilding). The "RAID" LED will glow amber if this occurs.
7.6 RAID Alarm Buzzer
This buzzer will sound when the RAID has failed or is invalid.
The "RAID" LED will glow red if this occurs.
7.7 Temperature Sliders
When your RAX QR reaches a certain temperature, buzzers
sound and the fan kicks on. You may want to change these
default temperatures according to your environment. With these
"sliders," you can change the default temperatures of the:
•
Enclosure fan kick-on
•
Enclosure Temperature Alarm
•
Drive Temperature Warning
•
Drive Temperature Alarm
U s e r M a n u a l f o r R A X Q R ( A9-210-0009) REV 1.0
- 8 -