This unit is NOT explosion proof!! NEVER operate unit without
cover in place and secured!!
15. Secure all hoses and wires using tie wraps. Be careful not to restrict
water flow or have moving parts come in contact with wires or hoses.
Place boat in water or connect water source to inlet fitting. Turn the unit
on . Water should begin to flow in 10-15 seconds. It takes approximately
10-15 minutes for the unit to reach maximum cooling capacity.
Remember if the pump can not pickup water when moving then the unit
will not operate.
Caution: If water does not begin to flow within 1 minute shut unit off
and check all connections. Check for leaks and make certain all
connections are secure. Fuses are located inside the unit. If the unit fails
to turn on, check to see that all fuse's are good. NEVER operate unit
without top cover in place!! Improper Servicing can lead to fire,
electrocution, or explosion. Never service, repair or troubleshoot a
system unless you are a professional service person. Bi monthly check
internal flexible lines for leaks and repair or replace if necessary.
Note: All Electric and refrigerant charging and recovery needs to be done by a qualified
individual.
Additional parts required
Qty. 12 -1" hose clamps
Qty. 4 gauge ring terminals
Qty. 1-Ball Valve brass 1/2"
Qty. 1
Underwater marine sealant
-
Qty. 1-female 1/2" NPT to 1/2" nipple brass fitting
Qty. 1- male 1/2" NPT to 1/2" nipple brass fitting