Aeon Labs AEOEZW062 Manual de início rápido - Página 7

Procurar online ou descarregar pdf Manual de início rápido para Controlador Aeon Labs AEOEZW062. Aeon Labs AEOEZW062 12 páginas. Garage door controller

Aeon Labs AEOEZW062 Manual de início rápido
A Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different device, the
controlling device needs to maintain a list of devices that will receive controlling commands.
These lists are called association groups and they are always related to certain events (e.g.
button pressed, sensor triggers, ...). In case the event happens all devices stored in the
respective association group will receive a common wireless command.
Association Groups:
Group 1 is assigned to the Lifeline association group and every device has 5 nodes to
associate. When the Garage Door controller is received the commands sent by controller to
1
be turned on or off, the Garage Door controller will send a basic report of its status to the
nodes in association group 1. To change what kind of signal is sent to the nodes in group 1,
please see the detailed description of configuration parameter 80. (max. nodes in group: 5)
When the Garage Door Controller receives the Basic Set, Switch Binary Set,commands
2
from main controller. it will forward the Basic Set, Switch Binary Set to associated nodes
in Group 2. (max. nodes in group: 5)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain
configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow to configure signed values. In order to set values
in the range 128 ... 255 the value sent in the application shall be the desired value minus 256.
For example: to set a parameter to 200  it may be needed to set a value of 200 minus 256 =
minus 56. In case of two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.
Startup Ringtone (Parameter Number 32, Parameter Size 1) Configure the default startup
ringtone.
Value
0
Disable the startup ringtone.
1 — 100 Enable and select a startup ringtone for the Garage Door Controller. (Default 1)
Sensor Calibration (Parameter Number 34, Parameter Size 1) Calibration Steps: 1. Let the
garage door move to full close position. 2. Send this parameter (34) with "value=1" to Garage
Door Controller. 3. Let the garage door move to full open position. 4. Let the garage door
move to full close position after the step 3 is completed. After the step 4 is complete, all
calibration steps are complete.
Value
Description
1
Enable calibration.
Timeout of Calibration Steps (Parameter Number 35, Parameter Size 2) Set the timeout of all
calibration steps for the Sensor.
Value
1 — 32767 Set the timeout of calibration. (Default 60)
Alarm Music (Parameter Number 36, Parameter Size 1) Get the numbers of alarm music.(not
support Set CC)
Description
Description