Function description
Schematic, operating element and display
L1
SET
24 V DC
A1 A2 O1 O2
Terminal description
A1/ A2
Power supply 24V DC
L1, L2, L3
Measuring inputs are to be connected directly to the motor, without switching contacts between.
Q
Acknowledgment input can be parameterized, manually or automatically
13/14, 23/24
Enabling contacts (2 NO-contacts). These switch off immediately if the parameterized speeds are
undershot or exceeded or internal or external errors.
13/14, 23/24 are to be used in such a way that the intended safety function, e.g. emergency stop is
executed.
O1, O2
Digital positive switching semiconductor outputs for the transmission of switching states to a
higher-level control for diagnostic tasks.
10
L2
L3
b8
OK
b4
SPEED
b2
b1
Q
13 14 23 24
L1, L2, L3
Measuring inputs
A1
Power supply
+24V DC
A2
0V
Q
Acknowledgment in-
put
O1, O2
Diagnostics outputs
13-14/23-24
Enabling contacts
SET
Configuration button
b1, b2, b4, b8 parameter 1-15
OK
Ready for operation
SPEED
Speed Status
18-09-27 / 33pd02-V0743