DNSR-2R2
Original Betriebsanleitung

Technical data

General technical data
Power supply
Current drain
Fuse
Operating temperature
Storage temperature
Vibration and Shock resistance in all 3 level
Cable cross section
Connection terminals/ Materiel
Connection wire
Housing material
Protection class
Rated Isolation voltage
Technical data of the inputs
S12
S22
Technical data of the contact outputs
OFF-time delay (t1) for 17-18
ON-time delay (t2) for 27-28
OFF-time delay (t1) for 17-18
OFF-time delay (t2) for 27-28
Switch current; contacts
according to IEC/EN 60947-4-1 for 17-18, 27-28 only
Switch current according to IEC/EN 60947-5-1 for 17-
18, 27-28 only
Switch current according to
IEC/EN 60947-5-1 for 17-18, 27-28 only
Switch current; contacts 15-16 and 25-26
Switch current; contacts 13-14 and 23-22
Short-circuit strength / line fuse
Mechanical life
Contact material
Maximal cycles for 17-18, 27-28 only
Isolation voltage
Impulse withstand voltage
pollution degree 2 environment
Reaction time / Drop out time
Wight

Contact life

1000
500
100
50
10
Stand 30.08.2017
AC15: 250V
DC13: 30V
0.1
Schaltstrom (A) / Switching current (A)
Seite 14 von 16
Original Instruction Manual
24VDC +/- 10%
ca. 80mA relay off, ca. 140mA relay on
Internal PTC fuse 200mA
-10°C to +60°C /
40°C to +80°C
Sin 10 – 50 Hz, 0,35mm, 10 cycles, 1 Octave / 5g
0.25-2,5mm² with wire end sleeve
Spring load clamps, pluggable/ Polyamide PA
60/75°C copper
Polyamide PA non-reinforced
Installation in a closed cabinet with ≥ IP54, terminals: IP20
250V AC not for the contacts 15-16 and 25-26
15V ± 0.5V, internal at S11, S33 test against other voltage
12V ± 0.5V, internal at S21, S43 test against other voltage
0.5 - 3s (t1 is for 15-16 ON time delay) with ID-No.: 33SR20
30-100s (t2 is for 25-26 OFF-time delay) with ID-No.: 33SR20
1,5s at ID-No.: 33SR15 and 33SR16, 12s at 33SR17, 33SR18
45s at ID-No.: 33SR15, 100s at 33SR16, 5s at 33SR17, 33SR18
AC1: 250V/3A, DC1: 30V/3A, 1.5x10
AC15: 250V/0.2A, DC13: 30V/0.2A, 10
AC15: 250V/1A, DC13: 30V/1A, 1.5x10
Minimal 24V/3mA, maximal 30V/0.5A, fuse 3A slow
Minimal 24V/3mA, maximal 30V/0.5A, fuse 3A slow
200A/ B6 automat / 800A/safety fuse 6A gG
> 20 x 106 cycles
AgNi10
360 cycles/h with maximal switch current AC15 + DC13
17-18 and 27-28: 250V AC/ 15-16 and 25-26: 30V
4KV, for the contacts 17-18 and 27-28 only
Typical 10ms / Typical 6ms
150g
2.0
0.5
1.0
Date 2017-08-30
cycles
5
cycles
6
cycles
5
AC1: 250V
DC1: 30V
3.0 4.0
5.0
Page 14 of 16