Dinel CLS-23 Manual - Página 5
Procurar online ou descarregar pdf Manual para Acessórios Dinel CLS-23. Dinel CLS-23 20 páginas. Capacitive level sesors
Também para Dinel CLS-23: Manual de instruções (18 páginas)
3 . b
rieF
Capacitive level sensors (switches) CLS–23 are designed for limit level detection of electrically
conductive and non-conductive fluids in vessels, reservoirs, sumps, pipes, tanks, etc. The sensitiv-
ity of the sensor can be easily set by placing magnetic pen on sensitive spot.
The process coupling at the housing can be with metric thread (M18x1.5 ; M20x1.5), pipe thread
(G3/8" ; G1/2") or sealing thread (NPT 1/2–14). Output performances – transistor output with open
collector (PNP), two wire electronic switch (S) and NAMUR output.
There are next performances available: N – Normal for non-explosive areas, E – Extended tem-
perature range for non-explosives areas, Xi – Explosion proof (intrinsically safe for explosive ar-
eas), NT – High temperature variant for non-explosives areas and XiT – High temperature variant
for explosive areas.
4 . F
eatUres
oF
CLS –23_ –10
CLS –23_–11
CLS –23_ –12
Electrode length 30 mm
CLS –23_ –20
Electrode length from 50 mm to 1 m.
CLS –23_ –21
CLS –23_ –30
© Dinel, s.r.o.
CLS–23
variants
Uncoated short bar electrode, for sensing of electrically non-conductive
liquids (mineral and plant oils,resins, etc.). Mounting in horizontal position.
Electrode length 30 mm.
Insulated (coated) short bar electrode, for non-aggressive electrically
conductive liquid sensing (water, water solutions). The insulation is made
from PP (Polypropylene).
Electrode length 30 mm.
Insulated (coated) short bar electrode, for moderately aggressive electri
cally conductive liquid sensing (chemicals, water, moderately aggressive
water solutions). Higher temperature resistance than variant "11". The insula
tion is made from FEP (Tetrafluoroethylene-Perfluoro-Propylene).
Partly insulated rod electrode, for level detection of conductive and non-
conductive liquids, partially resistant to vapours (water) condensation in the
sensing area. The insulation is made from FEP. Vertical mounting; horizontal
mounting (from the side) is possible for shorter electrodes (up to 200 mm)
Fully insulated rod electrode, for universal use, for level detection of con
ductive liquids (water, water solutions). Resistant to vapours (water) conden
sation in the sensing area and partially resistant to medium
spraying. The insulation is made from FEP. Vertical mounting; horizontal
mounting (from the side) is possible for shorter electrodes (up to 200 mm).
Electrode length from 50 mm to 1 m.
Uncoated removable rod electrode, for level detection of conductive and
non-conductive liquids. Vertical mounting; horizontal mounting (from the
side) is possible for shorter electrodes (up to 200 mm).
Electrode length from 50 mm to 1 m.
5