12 . Use, manipulation and maintenance
Detection of approach or assessment of the movement of solid objects, level indication in electri-
cally non-conductive storage tanks (plastic, glass) and level gauges. Limit sensing of non-abrasive 
bulk-solid materials (cereals, grains, granulates, sand, etc.) in metal storage tanks. Detection of the 
presence of liquids in the inter-wall area of double-walled storage tanks, liquid leakage detection in 
interception traps, concrete sumps or directly on the floor.
We do not recommend using for the measurement of el. conductive liquids that leave a
continuous film on the inner wall of an el. non-conductive storage tank or level gauge and
liquids that exude el. conductive particles that deposit themselves on the wall of a storage
tank or level gauge (e.g. heavily mineralised water, chemically treated waste water). Likewise,
the sensor is also not intended for measuring levels on level gauges and walls of storage
tanks with antistatic treatment (partially electrically conductive).
13 . General, conditions and warranty
Dinel, s.r.o. guarantees for the period of three (3) years that the product has the characteristics as 
mentioned in the technical specification.
Dinel, s.r.o. is liable for defects ascertained within the warranty period and were claimed in writing.
This guarantee does not cover the damages resulting from misuse, improper installation or incorrect 
maintenance.
This guarantee ceases when the user or the other person makes any changes on the product or the 
product is mechanically or chemically damaged, or the serial number is not readable.
The warranty certificate must be presented to exercise a claim.
In the case of a rightful complaint, we will replace the product or its defective part. In both cases, the 
warranty period is extended by the period of repair.
14 . Marking of labels
Labels for device of the type CPS-24N-_-NO, CPS-24N-_-NC, CPS-24N-_-PO, CPS-24N-_-PC:
BN
BK
BU
BN
BK
BU
BN
BK
BU
© Dinel, s.r.o.
CPS–24
CPS-24N-_-NO
Cable: __ m
s
0 ÷ 10 mm
+U
n
U
7 ÷ 36 VDC
I
3 / 7 mA
0V
Iomax
200 mA
CPS-24N-_-NC
Cable: __ m
s
0 ÷ 10 mm
+U
n
U
7 ÷ 36 VDC
I
3 / 7 mA
0V
Iomax
200 mA
CPS-24N-_-PO
Cable: __ m
s
0 ÷ 10 mm
+U
n
U
7 ÷ 36 VDC
I
3 / 7 mA
0V
Iomax
200 mA
CPS-24N-_-PC
Cable: __ m
No.: ______
Dinel, s.r.o.
U Tescomy 249
760 01 Zlín
Czech Republic
www.dinel.cz
IP67
IP67
No.: ______
Dinel, s.r.o.
U Tescomy 249
760 01 Zlín
Czech Republic
www.dinel.cz
IP67
IP67
No.: ______
Dinel, s.r.o.
U Tescomy 249
760 01 Zlín
Czech Republic
www.dinel.cz
IP67
IP67
No.: ______
Dinel, s.r.o.
10